Huawei CE16808 AC Bundle2 AC/HVDC Assembly Chassis, 2*MPUD, 5*SFU08G, 4* 3000W AC & HVDC, full Fans (CE16808A-B02)

Harga Hubungi Kami 

Deskripsi

Technical specifications 

Item Specification
Dimensions with packaging (H x W x D) [mm (in.)] 730 mm x 770 mm x 1150 mm (28.74 in. x 30.31 in. x 45.28 in.)
Dimensions without packaging (H x W x D) [mm (in.)] 438 mm x 483 mm x 985 mm (17.24 in. x 19.02 in. x 38.78 in.) (including mounting brackets)
Weight without packaging [kg (lb)] 98.1 kg (216.31 lb) (including two MPUs and filler panels)
Weight without packaging (full configuration) [kg (lb)] 163.6 kg (360.74 lb)
Weight with packaging [kg (lb)] 142 kg (313.11 lb)
Cabinet installation standards A812
Chassis height [U] 9.8 U
Redundant MPUs 1:1
Redundant Switch fabrics N+M
Power supply mode DC
Number of power modules 6
Redundant power supply
  • Dual-input power supply system: N+1 backup is recommended.
  • Single-input power supply system: N+1 backup

Dual-input power supply is recommended to ensure reliability.

Rated input voltage [V] -48 V/-60 V
Input voltage range [V] -40 V to -72 V
Maximum input current [A] 58.5 A for the voltage of -40 V
Maximum output power [W]
  • In 5+1 backup mode: 2200 W x 5 = 11000 W
  • In 6+0 backup mode: 2200 W x 6 = 13200 W
Certification
  • Compliance with safety standards
  • Compliance with EMC standards
  • Compliance with environment and environmental protection standards
Redundant fans Fan modules work in hot standby mode. At the normal temperature range, the system can operate properly for a short time after a single fan module fails. You are advised to replace the faulty fan module immediately.
Heat dissipation mode Heat dissipation using fans
Airflow direction Front-to-back airflow
Availability 0.9999971695
MTBF [year] 34.93 year
MTTR [hour] 1 hour
Long-term operating altitude [m (ft.)] ≤ 5000 m (16404 ft.) (When the altitude is between 1800 m and 5000 m (5906 ft. and 16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.).)
Long-term operating relative humidity [RH] 5% RH to 85% RH, noncondensing
Long-term operating temperature [°C (°F)] 0°C to 40°C (32°F to 104°F)
Storage altitude [m (ft.)] ≤ 5000 m (16404 ft.)
Storage relative humidity [RH] 5% RH to 95% RH, noncondensing
Storage temperature [°C (°F)] -40ºC to +70ºC (-40°F to +158°F)